Full Version: Universal Laser Tube charging

From: James (TILER02) [#6]
 4 Sep 2006
To: Harvey only (HARVEY-ONLY) [#5] 4 Sep 2006

Vytecs service rates about -100 I have it cutting, sort of, I have slowed the speed down to 5 ips. I am now cutting thru the paper mask. I think with 2 cuts I will be able to get what I need. but each run will take about 7 hrs.

From: Harvey only (HARVEY-ONLY) [#7]
 4 Sep 2006
To: James (TILER02) [#6] 4 Sep 2006

That is far too long, but if it gets it done, it gets it done.

Just be sure to check the window, if it is dirty, all of the heat normally generated will be in that one spot. Fractures and cracks will form.

What I have heard, it usually is not the tube itself that usually goes, it is the RF (Radio Frequency) circuitry that goes.

-100% is fairly poor in service quality.

Wish I could be of help. There do not seem to be others that frequent the forum with that laser that know the answer.


From: laserman (MIKEMAC) [#8]
 5 Sep 2006
To: James (TILER02) [#6] 5 Sep 2006

James,

What you need to do is first get ahold of customer service at ULS 1-480-609-0297. Give them the serial number on the laser tube, Tell them that it is on a Vytec system.

They will then let you know what to do.


From: James (TILER02) [#9]
 5 Sep 2006
To: laserman (MIKEMAC) [#8] 5 Sep 2006

Thanks Mike