Folder Laser Engravingepilog legend 24ex problem


Warning Press Ctrl+Enter to quickly submit your post
Quick Reply  
✏✏✏✏✏✏✏✏✏✏
 
 
  

Next
 From:  bd (BDFINALLY)
 To:  ALL
6391.1 
anyone have the breaker trip on the control board, when your trying to set a new home position? thanks

EDITED: 21 Mar 2007 by DGL

 

Previous
Next
 From:  Engravin' Dave (DATAKES)
 To:  bd (BDFINALLY) 
6391.2 In reply to 6391.1 
That's a new one to me. Have you called Epilog support?

Previous
Next
 From:  Boz (CHEDDARHEAD)
 To:  ALL
6391.3 

BD, when does the breaker trip? Does it trip when you are jogging the X and Y axis to the new position? Does it trip when you are moving one of the axis?

Or does it trip when you select the new home position and hit return?

You are running an Epilog Legend 24EX, with what power laser? What is your line voltage going into the machine? 110VAC, 220VAC?

Robert H. Bosworth
ACCESS Business Solutions, Inc.
Hudson, WI. 54016
(715) 386-8021
www.usedlasers.com

 

Previous
 From:  bd (BDFINALLY)
 To:  Boz (CHEDDARHEAD) 
6391.4 In reply to 6391.3 
the first time it tripped at the home position, the second time when i was trying to calibrate a new x position. yes, i've talked to them several times now and they're responding to the issue, but thought i'd tap this resource also. power is 110v

EDITED: 22 Mar 2007 by BDFINALLY

 
 
     
 